We are founder members of the Basement
Living Group , a marketing group promoting the conversion of areas below
ground into useful living spaces. Members are chosen because of their
reliability and expertise in this complex field. Please view the website.
Some explanation is given below as to how we do this, including definitions
of various systems, the ones we chose, and some of the pitfalls.
There is a British Standard to help with the design of water proofing systems
for basements : BS8102: 2009
Code of practice for protection of structures against water from the ground.
All good companies, with qualified surveyors (C.S.S.W. - Certified Surveyor
in Structural Water-proofing), will refer to this standard early on in
discussions with you. Those that don't should be avoided!
Any specification you are offered should state clearly if it is to BS8102 or
not. Those that are, require the surveyor to design a water proofing system that
can be expected to withstand entry of ground water into your basement. Note:
this does not normally include water that arises from leaking drains - although
the system might well deal with that too.
Those systems not to BS8102 are unlikely to come with any guarantee against
water entry from the ground, and will have no protection against flooding. In
most cases these conversions have excluded the drainage part of the system
(often to save cost) and so can only be described as dry lining systems. There
is more on this below.
To avoid confusion, the best way to refer to these treatments for existing
basement /
cellars, is to refer to "water proofing". This can then be sub-divided
into tanking and cavity drainage membrane (CDM) systems. There are other methods
of tanking for new-build structures that are not covered here. Tanking encompasses structures that
include membranes incorporated into the structure, either outside, inside or
sandwiched between masonry components. Tanking also includes waterproofing
conveyed by waterproof reinforced concrete structures, which are defined by
specific British Standards, specifically relating to the concrete. CDM systems always include a membrane, always
include a sump / pump or gravity drainage system and are always based on allowing water to
enter the building structure and then for it to be removed in a controlled way
by the drainage system. The membranes are there to direct water into the drainage system ansd to offer a dry surface for
internal finishes. A CDM system without drainage can not be a CDM system by
definition, and is referred to as a dry lining system.
Tanking is the term often used to refer to the waterproofing of basements /
cellars. In fact, tanking is defined as a continuous and completely waterproof
membrane applied over a masonry surface, preventing completely the entry of
liquid water under hydrostatic (water) pressure.
Basement / cellar waterproofing
is often carried out using CDM systems or dry lining
systems. The CDM systems allow water to enter behind the membrane and directs the
water to sumps and conventional gravity drainage, or to active drainage systems, such
as sumps with pumps. Dry lining systems cover
walls (and maybe floors), without the provision of any sump / pump or gravity drainage, on
the assumption that liquid entry of water will not occur at any time in the
future. This is a risky assumption as changing weather patterns in the UK mean
that cellars that have been converted without sump / pump or gravity drainage, risk
flooding. This is because no membrane system can be expected to hold back a head
of water. The water has to be allowed to drain somewhere.
Understanding the principles involved in waterproofing a structure allows the
risk of failure of the system applied to be reduced to an acceptable level.
Furthermore, with forethought, systems can be used where, should problems occur,
remedial / repair work can be carried out without excessive disruption.
Basement / cellar waterproofing is the application of a covering to masonry
usually, but not necessarily, below
ground, to prevent or control penetrating dampness or water ingress. The masonry
can be treated from outside or inside, but most waterproofing to existing buildings is
carried out from inside, as access to the outside is not possible or practical. Waterproofing and the types of systems in use is a complex
subject. We cover only the basic details here. Each project will have its own
conditions and requirements and therefore require specific expert advice.
The type of waterproofing chosen depends on the conditions which it is trying
to deal with. This is the control of water vapour, or a little liquid water
or considerable amounts of water. The use to which the area will be put is also
important. Both tanking and CDM systems can deal with all
of the above, but the performance of each system has different results and
different effects on the structure to which it is being applied. This is such an
important feature that in some cases only one of the system types will be
suitable. Choice of the wrong system could result in structural failure of the
building components. This is another reason why expert advice is needed.
Methods of Waterproofing Existing Basements / Cellars
- Cement coatings and multi-coat render systems (tanking)
- Epoxy resins and bituminous coatings (liquid applied membranes - also
tanking), applied inside the structure
- Externally acting liquid epoxy resins, installed from inside the
structure, acting from the outside - these are new systems
- Cavity drainage membranes (Type C, drained protection, as defined by BS8102 : 2009)
Both 1 and 2 require a high level of original surface preparation as
these coatings are designed to stick or key to the walls being tanked. If they
fail to key then water under hydrostatic pressure (penetrating dampness
below ground) can force the material to debond from the original surface and
break the tanked surface. For this reason this company chooses to use mainly
cavity drainage membranes for its waterproofing work. The exception to this is in
circumstances where these cavity drainage membranes can not be applied. Here we use cement
tanking products. We do not use any of the other methods in 1 and 2 above.
Recently we have examined the systems in 3. above, provided by MC Chemicals.
We consider their range of products for use on specific projects that justify
that approach.
We
are asked frequently not to include a sump / pump drainage system in our work,
usually because the client is happy with the level of flood risk associated with having
no drainage. This is a cost / risk assessment by the client. In these cases we
are installing a dry lining system only, and such systems are outside of, and do
not comply with, BS8102: 2009.
Cement tanking is applied to prepared surfaces like plaster, either
with a brush or trowel, to form a layer of material through which water should
not move. This may be plastered over to give the dry finished internal surface.
Cavity Drainage Membranes
Cavity drainage membranes are formed from high density polyethylene. They
have a profile similar to the sole of a football boot and are often called
studded membranes. When the studs are up against the wall an air gap
of about 5 litres per square metre is formed between the membrane and the wall
(depending on the profile of the studs).
This may or may not be ventilated, but will allow any free water to run behind
it, under the influence of gravity.
The membrane is loosely mechanically fixed to original sound wall surfaces, usually with
treated battens or other framing systems, on to which insulation and plasterboard can be fixed. In some circumstances
the battens can be omitted and plasterboard and membrane fixed directly using special plastic plugs.
There are also versions including polypropylene mesh welded to the membrane,
onto which plaster can be applied directly.
With regard to internal finishes, the object of waterproofing, by whichever method, is to put a layer of waterproof
material between the damp wall or floor and the internal finish. This will prevent
the inner material from being in direct contact with wet masonry. None of the
systems eliminate the occurrence of water vapour in a treated area, so
consideration needs to be given to controlling / reducing relative humidity using
ventilation, air conditioning, dehumidification or some other method.
Recently Building Regulations have been updated to require that internal
finishes provide improved levels of thermal insulation and sound proofing in
some circumstances. In these cases we are able to apply insulated plaster boards
and other insulation to walls and floors, as well as the range of sound reducing
plaster boards that are available.
Other finishes are possible depending on the final use of the converted area.
These include membrane only, plywood, timber panelling and other wall boarding
materials. The finish chosen will be governed by the use to which the converted
area is put.
Area use specification
In simple terms the specification for structural waterproofing against use is
shown below.
| Storage |
Low specification |
| Utility/Kitchen/Basic office |
Higher specification |
| Bedroom/Dining area/Lounge |
Formation of habitable room - highest specification |
British Standard BS8102 : 2009 - Code of Practise for Protection of Structures
Against Water from the Ground defines performance levels for the dryness of
buildings in three grades as follows :-
| Grade |
Basement Usage |
Performance Level |
| 1 |
Car parking, plant rooms (excluding electrical equipment),
workshops |
Some water seepage and damp patches tolerable |
| 2 |
Workshops and plant rooms requiring drier environment,
retail storage areas |
No water penetration but moisture vapour tolerable |
| 3 |
Ventilated residential and working areas, including offices,
restaurants, leisure centres etc. |
Dry environment. Humidity control required |
Within BS8102, grades 2,and 3 require the same application of CDM systems
in each case. What varies is the amount of air humidity control; escalating up
from, say, air bricks, forced electric ventilation, heat exchange ventilation,
dehumidification and total air conditioning. The drier the enviroment required the more air conditioning is needed.
Conversion considerations
We have found the requirements of our clients to be very varied and each
basement must be treated on its own merits given the individual circumstances
found. Consideration must be given to the
following:-
| Does the area flood? |
Sump and pump required. Risk vs. cost |
| How much will it cost? |
Type of area to be formed and what is there at the moment
Budget - how much do we have to
spend?
|
| Other connected items |
Foundations - will they become exposed ?
Floors - damp ? - level ? - final floor finish ?
Other walls e.g. partition walls
Internal joinery - doors, architraves, skirting boards etc.
Ceilings - hiding pipe and wire runs ? - head height ?
Windows and external doors - natural light and ventilation
Services (plumbing, drainage and electrical systems)
Ground levels, soil type and position of drains outside
Sound and thermal insulation
Heating, ventilation and condensation control
Planning, Building and Environmental Health Regulations
Fire escapes and alarms, and security alarms
|
We can prepare an individual report and specification for the damp proofing
of each basement we
inspect. Sometimes we advise clients that their ideas are not possible, or that
they are only possible to one of the lower specifications. The British
Standard - BS8102 : 2009 - sets the standards for such works, but
often we find that the basement or client's
requirements / circumstances do not allow or require for such systems to be installed. It is usually down to use
(and therefore specification) versus cost. However, we do try to carry out
our assessment of the conversion to the British Standard, and use as many of its
practices within our recommendations. Our starting point for the assessment is
always with the British Standard.
Most recent Building Regulations, and BS8102, require designers of water proofing sytems to consider contamination of sites by ground gases.
Radon and other ground gases, such as methane, are now more recognised as contributors to health and safety in buildings – and especially basements.
Those designing basement systems must consider the possibility of ground gases in any design, and this is now a requirement of Building Regulations and Codes of Practise.
A desk based on-line search can be done to locate the risk of radon at your property. We automatically offer this for you as part of our design service for basements.
The outcome of any radon search will categorise the ground around the property as requiring no action, or a basic radon barrier system, or a full positive ventilation radon control system.
The latter two require the introduction of addition materials and installation techniques to create a system to provide the level of protection designated.
The positive ventilation system requires additional components to force air to move behind membranes to extract ground gases, such as radon.
These systems have additional costs over and above standard basement water proofing, but the costs can be controlled by designing in ground gas control as an integral part of the water proofing system.
The UK maps identifying areas of high radon contamination can be seen at UKRadon.org website.
Getting it Right
The law places a duty of care on us
as experts to provide the fullest information to our clients. This places a
burden onto our surveyors and the company, particularly in the current litigious
climate. As a result of this our reports and specifications may contain one or
more of the paragraphs below. They are repeated here to help clarify
our approach to various items which are critical to the success of any
work. One of the main points of concern for us is to make sure the client
understands the risk of future flooding. A basement that has "never
flooded" to the knowledge of the client, might flood tomorrow. The
paragraphs below provide a warning about the risks of flooding when a drainage system is not included in the
specification. We want our clients to be able to make an informed decision of
the risk taken when they chose not to include a sump and pump in their
specification (and therefore take the specification outside of BS8102 : 2009).
Paragraphs that we use standard in our correspondence are given below:-
British Standard
"The client should note that there is a British Standard for the design
of waterproofing systems for both new and existing basements - BS8102 : 2009 The
Protection of Structures against Water from the Ground. The system specified
in this report is not to this standard. However, we have chosen elements
from the standard, choosing system and material components to provide a
satisfactory degree of water tightness (as defined by the standard), suit the
client’s cost/budget and fulfil the client’s performance requirements.
Please note that a system fully complying with BS8102 : 2009 is available and
has a higher cost."
Flooding
"The client should note that
the work we propose will not prevent the cellar/basement from flooding, (e.g.
from leaking drains, burst pipes, changes to the existing water table height)
should such circumstances arise. The membrane application we will carry out
deals with penetrating vapour dampness from high ground levels and not the
physical liquid entry of water under hydrostatic pressure. Only a higher
specification system using a weather-lapped cavity drainage membrane, linked
into sub-floor drainage or a sump/pump system, will overcome such a situation.
This has not been allowed for in this quotation. Recent case law has
suggested that specifiers of underground waterproofing systems need to specify
these on the assumption that the primary waterproof barrier will be less than
adequate. This means that our specification would need to be at a level above
that given in this report, and the result of this would be a system that may be
outside the range of the client’s budget. A higher specification for such a
waterproofing system is available to the client at their request. Such systems
cost more. Please discuss this with this office."
Electrical and Plumbing Systems
"Where membrane dry-lining is to be applied to walls the existing
plumbing and electrical installation (sockets and light switches) will require
modification due to the thickness of the new finish.
This must be carried out by the client’s own plumber or electrician (a
“first fix”) prior to the arrival of our operators on site."
We normally recommend that electrical wire runs are made behind the plaster
board surface to hide the wires and that plumbing pipe runs are made on the
surface of the walls for future access. This means that the electrical first fix
should include for the running of wires to the individual electrical points,
without connection to the supply. This is followed by a second electrical fix,
when the back boxes and face plates are installed. The first fix for plumbing
should allow for the introduction of pipes into the basement area terminated at
isolation valves, with the system being extended from these points as part of
the second fix when the plaster boards and skim plastering has been completed.
Condensation control
"In the areas treated there may
still be significant levels of background water vapour after our work, and in
the future, which needs to be controlled to avoid condensation. Some of this
condensation may occur on internal finished surfaces and be easy to detect and
deal with. However, a more difficult problem is that caused by interstitial
condensation. This occurs when condensation takes place behind wall linings.
This is harder to detect, and the first signs of this may be damp patches on the
floor, where water has run down the studded membrane inside the
waterproofing system. The system is not designed to deal with this problem, so
the client needs to ensure that condensation is prevented by providing a
satisfactory balance between background heating and ventilation. High levels of
relative humidity must not be allowed to develop in these areas and this will
require the use of forced electric ventilation to areas of moisture production
(e.g. kitchens and bathrooms – part of the Building Regulations). In some
situations it might become necessary for the client to introduce
dehumidification, or other forms of condensation control, into a newly treated
area to forcibly reduce humidity levels. The need for this may not become known
until the water proofing system has had time to "settle". Relative
humidity in these areas must be reduced to an acceptable level by ventilation,
air conditioning, dehumidification or other means. Further advice on
condensation control is available from this office."
Planning, Building and Environmental Health Regulations
"There are regulations
concerning the conversion of dwellings, including basements, under Planning,
Building and Environmental Health controls. These relate to all properties. The
client should satisfy themselves that this work complies with such regulations.
If there is any doubt concerning this, the relevant authority should be
consulted. In particular, new Building Regulations called “Part L”
(concerning thermal insulation), “Part E” (concerning sound insulation) and
“Part F” (concerning ventilation) have recently been adopted. We can advise
further on this, if required."
Recently, as part of a complete re-appraisal of Building Control Regulations,
new requirements have been introduced by the authorities. Our experience is that
the new regulations are interpreted and enforced by building control officers in
differing ways. The two main new areas are those of thermal (heat) insulation
(known as the part L regulations) and sound insulation (known as the part E
regulations). The regulations set out minimum criteria for the thermal insulation of walls, floors and ceilings. The
sound regulations deal with the reduction of sound "nuisance" between
properties and especially into bedrooms from adjoining rooms, even in the same
property.
Whatever emphasis the local building control officer places on these building
regulations, the conversion of a basement is a good opportunity to upgrade the
thermal and sound insulation of the areas converted, and other adjacent areas.
This improves the overall comfort of the property and in the longer term will
save money by reducing heating costs, and also improve the property's energy
efficiency rating. This is now and important feature of the new HIPS
seller's pack.
Floor / Wall interfaces (treatments to walls only)
"It will not be possible within this specification to
link the wall membrane to any floor membrane (if existing). This will leave a
weak point at the floor/wall interface, where moisture may enter. The solution
to this would be the full replacement of the floor, incorporating a damp proof
membrane beneath the new flooring concrete. The damp proof membrane should be
lapped up the walls by a minimum of 400 mm. Alternatively, if the floor is sound
(see below), studded membrane could be extended off the walls across the floor,
topped with a floating (optionally insulated) chipboard deck. This additional
work is not included in this quotation.
The existing solid floor may appear sound, but the client should be aware that
without a damp proof membrane, the floor concrete may be liable to sulphate
attack and heave in the future. We can provide a supplementary specification and
quotation for the formation of a new concrete floor incorporating a damp proof
membrane. For the work in this specification, we will proceed on the basis
that the client wishes to use the existing floor construction and that the risk
of future floor heave has been considered, but a new floor not chosen."
Survey and Inspection
The current recognised basement water proofing qualification
is C.S.S.W. - Certified Surveyor in Structural Water proofing. All projects that
include structural water proofing should be overseen by someone with that level
of qualification.
There is only one satisfactory way of determining if a
basement/cellar areas is suitable for conversion and that is by consulting
qualified experts. The expert should be invited to view the area so that a full
investigation of the potential for the area can be made. The person who is going
to be the end-user, client, bill payer or who has a direct interest in the
conversion MUST be present. This is so that the exact client requirements are
established, and especially so that the risks of flooding can be fully
discussed and understood. It is no good taking a decision to leave out a sump
and pump system to save money, and then be standing in inches of water years on.
It is even more unacceptable to be in the same position and not to have known
that it might happen. This problem is the most frequent cause for litigation
between the client and the installer - and this is to be expected. After all,
the client wanted a dry and useable basement !
|